MAINTENANCE
SECTION 5
Page 124 CMD-4081850 / 90-860094030 SEPTEMBER 2003
3. Attach a hose between the flushing attachment and a water source.
72012
a
b
Typical
a-Flushing Attachment
b-Hose
4. Lower sterndrive unit to full DOWN/IN position.
5. Partially open water tap (approximately 1/2 maximum capacity). Do not use full water
pressure.
6. Place remote control in NEUTRAL, IDLE speed position and start engine.
CAUTION
Do NOT run engine above 1500 rpm when flushing. Suction created by seawater
pickup pump may collapse flushing hose, causing engine to overheat.
7. Operate engine at IDLE speed in NEUTRAL for 10 minutes, then stop engine.
8. Shut off water tap.
9. If boat is in the water, raise sterndrive unit to TRAILER position.
10. Remove hose and flushing attachment.
Przeglądanie stron 131