Clearing Clogged Blue Drain Hoses (continued)
72693
2A
Engine Running
1 Attach UNCLOGGED blue drain hose to the bracket, leaving the
CLOGGED blue drain hose disconnected.
2 Install flushing attachment over water pickup holes (A) in gear
housing as shown.
3 Attach a hose between the flushing attachment and a water
supply.
4 Partially open water supply (approximately 1/2 maximum
capacity). DO NOT use full water pressure.
CAUTION
Ensure bilge pump is operating before beginning procedures.
Excess water in bilge can damage engine or cause boat to
sink.
5 Turn on the bilge pump.