145
CA798
Draining
CA853
Seawater (Raw-Water) Cooled Models
NOTE: This procedure will not work with 3.0L Single Point Drain
System. See specific instructions later in this manual.
CAUTION
If boat is to remain in water after draining, seawater inlet hose
must be removed and plugged to prevent a siphoning action
that may occur, allowing seawater to flow from the drain holes
or removed hoses.
IMPORTANT: Boat must be as level as possible to ensure
complete draining of cooling system.
CAUTION
Seawater section of cooling system MUST BE COMPLETELY
drained for winter storage, or immediately after cold weather
use, if the possibility of freezing temperatures exists. Failure
to comply may result in trapped water causing freeze and/or
corrosion damage to engine. Damage caused by freezing IS
NOT covered by the Mercury MerCruiser Limited Warranty.
1 Ensure engine is as level as possible to ensure complete draining
of cooling system.